Offshore oil rig at sunset

Need help with your Firestop? Start here.

Send us the quote, order question, spec, or project note. We will get it to the person who can actually help.

If you are bidding a job, checking on an order, or trying to match a product to a spec, start with AMFSS.

  • Quotes without guesswork Share the spec, deadline, and job details.
  • Order follow-up Ask about status, repeats, or account questions.
  • Project support Commercial, marine, industrial, and government work.
AMFSS fire safety shield logo
Real people, real follow-through Trade shows, site visits, and direct support from the AMFSS team.

Offshore fire safety

How Do Offshore Fires Start?

Offshore vessels and installations bring fuels, electrical systems, and hot machinery into close proximity. When combustible materials meet an ignition source, a fire can develop. Here are four common contributors.

Thermal

Heat & hot work

Hot surfaces, welding, cutting, and sparks can ignite nearby combustible materials or flammable vapours.

Electrical

Equipment & wiring faults

Damaged wiring, overloaded circuits, and faulty equipment can produce heat or sparks that start a fire.

Chemical

Flammable fuels & reactions

Fuel leaks can release flammable vapours. Incompatible chemicals can also react and generate dangerous heat.

Unsafe Work Practices

Handling & housekeeping

Improper storage, combustible waste, and missed safety procedures can allow fire hazards to build up.

What’s at stake

People

Fires can cause serious injuries and loss of life, putting crews and emergency responders at risk.

Equipment

Damage to vessels, machinery, and infrastructure can lead to costly repairs or replacement.

Operations

Shutdowns, inspections, and repairs can interrupt work and delay a return to service.

Frequently Asked Questions

What is AMFSS?

AMFSS is where customers reach American Fire Safety Supply for quotes, order follow-up, procurement help, and project questions.

When should I use AMFSS?

Use AMFSS when a request needs direct team follow-up. That includes quote requests, order follow-up, procurement coordination, account support, trade-show conversations, and project communication that needs to reach the operating team.

Do I need part numbers before I ask for help?

No. Send whatever you have: photos, specs, product names, job notes, or order history. We can help route it.

What kinds of buyers or projects does AMFSS support?

AMFSS routes requests from commercial construction teams, marine and offshore buyers, industrial maintenance and repeat-order stakeholders, and government procurement contacts. The point of the site is to make company support, quote routing, and project follow-up easy to find and use.

IMO FTP Codes

Application

Part 1, §§1.1–1.2: Materials required to be non-combustible are assessed under Part 1. Passing §3 allows that classification, including organic/inorganic mixtures.

Acceptance Criteria of Non-Combustibility

All four averages must meet these limits.

Part 1, §§3.1–3.4
Test resultLimit
Furnace temperature rise≤30 °C
Specimen surface temperature rise≤30 °C
Sustained flaming≤10 s
Mass loss≤50%
Classification Criteria

Dm is the average maximum specific optical density of smoke from three tests at each test condition.

Smoke — Part 2, §2.4.1
MaterialMaximum Dm
Bulkhead surfaces, linings and ceilings200
Primary deck coverings400
Floor coverings500
Plastic pipes400

Average maximum concentrations at each test condition; laboratory classification limits, not workplace exposure limits.

Toxicity — Part 2, §2.4.2
GasMaximum (ppm)
CO1,450
HBr600
HCl600
HCN140
HF600
SO₂120
NOₓ350

SO₂: 200 ppm for floor coverings.

Source & Applicability

Selected material-test criteria from the IMO 2010 Fire Test Procedures Code.

Read IMO resolution MSC.307(88) (PDF)

Material tests do not establish approval of a complete penetration system. Check the applicable rules, amendments and product approval documents.

Who we work with

Firestop supply across industries.

Commercial Construction

Contractors and project teams working from plans and specifications.

Marine & Offshore

Vessel, shipyard, and offshore installation projects.

Industrial Maintenance

Facility maintenance, repairs, and repeat orders.

Government Procurement

Buyers coordinating specifications, documentation, and purchasing requirements.

Order or quote request

Send what you have. We will sort out the rest.

Use the form for quotes, order follow-up, account questions, or project details. It goes to [email protected].

Complete the security check below before you send your request. If it does not load, email [email protected].

About AMFSS

Real people in real time.

Behind every order is a project and a person responsible for moving it forward. At American Fire Safety Supply, we bring a personal approach to serving commercial, marine, industrial, and government customers.

Mission

Help customers get the firestop products and information they need, with clear communication and care from the first question through order follow-up.

Vision

Build lasting relationships as a trusted firestop supplier, known for knowledgeable people, dependable service, and a commitment to learning and contributing.

“Innovation & Marketing produce results, all other elements in a business system are cost.”

— Peter Drucker